Reference Hub2
Development of Portable Medical Electronic Device for Infant Cry Recognition: A Primitive Experimental Study

Development of Portable Medical Electronic Device for Infant Cry Recognition: A Primitive Experimental Study

Natarajan Sriraam, S. Tejaswini, Ankita Arun Chavan
Copyright: © 2016 |Volume: 5 |Issue: 2 |Pages: 11
ISSN: 2161-1610|EISSN: 2161-1629|EISBN13: 9781466693715|DOI: 10.4018/IJBCE.2016070104
Cite Article Cite Article

MLA

Sriraam, Natarajan, et al. "Development of Portable Medical Electronic Device for Infant Cry Recognition: A Primitive Experimental Study." IJBCE vol.5, no.2 2016: pp.53-63. http://doi.org/10.4018/IJBCE.2016070104

APA

Sriraam, N., Tejaswini, S., & Chavan, A. A. (2016). Development of Portable Medical Electronic Device for Infant Cry Recognition: A Primitive Experimental Study. International Journal of Biomedical and Clinical Engineering (IJBCE), 5(2), 53-63. http://doi.org/10.4018/IJBCE.2016070104

Chicago

Sriraam, Natarajan, S. Tejaswini, and Ankita Arun Chavan. "Development of Portable Medical Electronic Device for Infant Cry Recognition: A Primitive Experimental Study," International Journal of Biomedical and Clinical Engineering (IJBCE) 5, no.2: 53-63. http://doi.org/10.4018/IJBCE.2016070104

Export Reference

Mendeley
Favorite Full-Issue Download

Abstract

Infant cry is considered as the first biological signal communicated by the newborns to the mother and the outside world. In NICU, there is a huge need to monitor the physiological conditions of the premature and full term infants. In such environment, the cry signal conveys significant information in terms of the distress of the infant and thereby needs of the infants can be well attended. Establishment of the portable device is thus essential for such scenario. This work enumerates a primitive experimental study on developing portable electronic medical device for infant cry recognition. The setup comprises of a voice recorder, NI My RIO processor with a Lab view followed by the LCD Tablet for display. The cry signals were recorded by placing the voice recorder in the incubator and were qualitatively assessed by the clinician and confirm its suitability for the experimental study. A threshold based classification was employed which sends the voice based alarm to the tablet. The continuous monitoring of such facility in NICU provides the behavioral status of the infant

Request Access

You do not own this content. Please login to recommend this title to your institution's librarian or purchase it from the IGI Global bookstore.